![]()
We’ve found creative solutions will limit cost impacts. ![]() Integrating the required sanitation facilities is often challenging, but the required number of fixtures is a fraction of what is required under the normal use of the space, whether a classroom or gym. The most efficient shelters are those that function as classrooms or gymnasiums when not in use as a shelter and, therefore, have the least amount of additional storm shelter only spaces or features. Comfort of occupants and certainly cost are considerations. Natural ventilation is preferred since most mechanical equipment is typically on the exterior and difficult to integrate within or protect against 250 mph winds. ![]() #SHELTER 3 PART1 GENERATOR#Should there be a loss of power, Uninterruptible Power Supplies (UPS) or a generator will be required to maintain emergency lighting, any plumbing supply/waste systems or sump pumps, and mechanical ventilation. #SHELTER 3 PART1 PORTABLE#The standard requires we provide critical support systems for two hours for a tornado shelter and 24 hours for a hurricane shelter, including functioning toilets, hand-washing stations (in some cases, portable units), a fire extinguisher, a place for a first aid kit, lights on back-up or battery power, and ventilation (mechanical or natural). ICC 500 defines critical support systems as structures, equipment, and components required to ensure the health, safety, and well-being of occupants. There are many things to consider, including occupant density, access, sanitation facilities, and impact protective systems (doors, window shutters.) Determining the right location for each project is not a one-size or location-fits-all scenario. In most schools, we are designing either a portion of a classroom wing or the gymnasium as the storm shelter. However, a basement level shelter with occupied floors above needs to be designed to withstand the collapse (impact) of the structure above, although any shelter that’s within a building’s fall zone would also need to resist the same. A shelter covered by more than 12 inches of soil does not need to be impact tested. ![]() We’ve designed several basement level or subgrade parking structure shelters when those spaces were already part of the programmed design. Both the 2018 IBC and IEBC limit the travel distance from any building served by the shelter to 1,000 feet. Chapter 4 Siting of the ICC 500 focuses on flood elevation, but the location also needs to be carefully analyzed for adjacent building collapse, debris, and proximity. #SHELTER 3 PART1 FREE#LocationĪ storm shelter may be free standing, attached to, or within a building. ![]() When designing storm shelters for K12 schools, there are three things to consider. The ICC 500 provides minimum design and construction requirements from structural design criteria, occupant density, critical support systems, and impact and pressure testing to name a few.įrom my team’s standpoint, our goal is to provide a shelter that protects its occupants and to ensure we’ve designed everything you might need to maintain safety, communications, and comfort. #SHELTER 3 PART1 CODE#The 2018 International Existing Building Code (IEBC) clarifies that an addition requires a storm shelter but is only required to house the occupant load of the addition, not the entire existing building or campus, if the addition is not otherwise planned to be large enough. The required capacity of the storm shelter is intended to be the expected number of students and staff on any given day or the capacity of the largest indoor assembly space, whichever is greater. The 2018 International Building Code (IBC) requires that all Group E occupancies that fall within FEMA’s 250 mph wind speed map with an occupant load of 50 or more have a storm shelter constructed in accordance with ICC 500, the ICC/NSSA standard for the design and construction of storm shelters. I’m a member of the National Storm Shelter Association’s (NSSA) Design Practices Committee, and the association’s purpose is to ensure its members produce the highest quality residential and community storm shelters for protecting people from injury or loss of life from the effects of tornadoes and other wind-related events. It’s officially storm season in tornado alley, and as an architect for education projects, keeping students safe is top of mind. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |